Model PRO 9549UG
Installation Manual
SELECTABLE FEATURES
Note : The method of manual override can either be selected to operate from the valet switch or operate as custom code. Be
certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.
Dip Switch Selectable Features :
Switch Number ON Position OFF Position Factory Default
Dip Switch 1 Custom Code Override Valet Switch Override Valet Switch Override
Dip Switch 2 Voltage Sense Hardwire Voltage Sense
Note : When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver’s door pin switch in order to
begin the passive arming sequence.
RF Programmable Features :
Feature Selection 1 Chirp 2 Chirps Default
First 1 Second Door Locks 3.5 Second Door Locks 1 Second
Second Auto Lock On Auto Lock Off Auto Lock Off
Third Auto Unlock On Auto Unlock Off Auto Unlock Off
Fourth Headlight Output On Headlight Output Off Headlight On
Fifth Passive Door Locks Active Door Locks Passive Locks
Sixth Passive Arming Active Arming Active Arming
To program these selectable features;
Action System Response
Turn ignition on No response
Flip valet switch on then off 3 times 1 Chirp - LED 1 flash
Within 3 seconds, turn ignition Off Short chirp, then long chirp
First Then On 1 chirp = 1 second door locks
Press the Lock/Unlock button to change 2 chirps = 3.5 second door locks
or
Second Flip valet switch on then off 2 chirps = auto locks off
Press the Lock/Unlock button to change 1 chirp = auto locks on
or
Third Flip valet switch on then off 2 chirps = auto unlock off
Press the Lock/Unlock button to change 1 chirp = auto unlock on
or
Fourth Flip valet switch on then off 1 chirp = headlight output on
Press the Lock/Unlock button to change 2 chirps = headlight output off
or
Fifth Flip valet switch on then off 1 chirp = passive locks
Press the Lock/Unlock button to change 2 chirps = active locks
or
Sixth Flip valet switch on then off 1 chirp = passive arming
Press the Lock/Unlock button to change 2 chirps = active arming
or
Flip valet switch on then off Exit program mode
or
Turn ignition key off Exit program mode
Note : Once you enter the feature programming mode, do not allow more than 15 seconds to pass between steps, or the
programming will be terminated.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Model PRO 9549UG

Page 1Model PRO 9549UGInstallation ManualSELECTABLE FEATURESNote : The method of manual override can either be selected to operate from the valet swit

Page 2

Page 2INSTALLATION OF MAJOR COMPONENTSControl Module :Select a mounitng location inside the passenger compartment ( up behind the dash ), and secure u

Page 3

Page 3When installing this system into vehicles with electronic “ after fans “, it is recommended you disable the voltagesense circuit.In voltage sens

Page 4

Page 4Mini 10 Pin Edge Connector :Light Green Wire : ( - ) Instant Trigger Zone 1This is an instant on ground trigger wire. This wire ( zone ) should

Page 5

Page 5This wire provides an immediate ground signal, and stays at ground for up to 8 seconds as long as the button(s) onthe keychain transmitter remai

Page 6

5 Wire Alternating Door Lock Circuits :In this application, it is necessary to cut the existing door lock by - pass wires. These wires run from the ma

Page 7 - CONTROL MODULE

Page 7RED87A858630CUTTOIGNITIONSWITCHTOSTARTSOLENOID87TO +12 VDCIGN./CRANKEXISTING LOW CURRENT SOLENOIDFEED WIRE (+12VDC, CRANKING ONLY)PRO 9549UGCO

Page 8

PRO 9549UGCONTROL MODULEBLACK2 STEP UNLOCKRELAY OUTPUTSTo Relay Terminal #85To Relay Terminal #86LT. BLUEL.E.D.ZONE 1Optional Negative TriggeringAlar